DOI:
工程科学与技术:2015,47(6):1-8
←前一篇   |   后一篇→
本文二维码信息
码上扫一扫!
新型PEC柱-钢梁端板连接组合框架层间抗震机理试验研究
(苏州科技学院)
Test Study on Seismic Mechanism of Interstory Substructure of Innovative PEC Column-Steel Beam Frame with End-Plate Connection
(University of Science & Technology of Suzhou)
摘要
图/表
参考文献
相似文献
本文已被:浏览 1196次   下载 28
投稿时间:2015-05-09    修订日期:2015-07-02
中文摘要: 良好的抗倒塌性能是维系结构在大震下的必要整体性、实现“大震不倒”抗震设防水准的关键所在。为研究新型卷边PEC柱-钢梁外伸端板连接组合框架结构的层间抗震机理,按1:2缩尺设计了1榀组合框架层间子结构模型试件并进行水平低周往复荷载试验。基于试验现象和测试数据,分析了试件结构的破坏过程与破坏模式、滞回特性、刚度退化、耗能能力、变形模式等抗震性能。研究结果表明:试件结构最终破坏模式为端板附近梁截面充分屈服形成塑性铰的理想塑性破坏机构;试件整体与层间位移延性系数μu=3.74和最大等效黏滞阻尼系(ζeq)max=0.325,具有良好抗震延性和耗能能力;试件结构整体性好、水平抗侧刚度沿高度分布均匀,水平位移分布规律表现为理想的倒三角弯剪型变形模式;试件结构整体与层间侧移和节点转角均超过大震层间侧移限值1/30,即试件结构具有良好的抗倒塌能力。
Abstract: Superior collapse-prevention performance of the building structure can maintain its abundant integrity to realize the design target of collapse prevention at MCE(maximum considered earthquake) level. To investigate the seismic mechanism of innovative PEC column—steel beam composite frame with end-plate and pretension penetrating bolts connection, a 1/2 scale test specimen of inter-story substructure was designed and tested under lateral low-cycle reserved loading. Based on the test observation and measurements, the seismic performance including the failure process and failure mode, the hysteretic property, lateral stiffness degradation, energy dissipation capacity and drift deformation pattern were analyzed. Test results showed that the failure mode was primary induced by the plastic hinge of beam section adjacent to end plate; the displacement ductility coefficient and maximum equivalent viscous damping ratio of the specimen are 3.74 and 0.325 respectively, and the specimen own better seismic ductility and energy-dissipation capacity; the drift pattern as ideal inverted triangle pattern of flexure-shear type was formed due to its excellent integrity and lateral stiffness is evenly distributed along its height; the interstory drift ratio and connection rotations all surpassed the drift limit(1/30) of maximum consideration earthquake, correspondingly the specimen owned sound collapse prevention capacity
文章编号:201500432     中图分类号:    文献标志码:
基金项目:国家自然科学基金:新型PEC柱-钢梁组合框架结构体系倒塌机理与设计方法(51078247);新型卷边PEC柱-钢梁部分自复位连接组合框架结构体系抗震机理与设计对策(51478286)
作者简介:
引用文本:
方有珍.新型PEC柱-钢梁端板连接组合框架层间抗震机理试验研究[J].工程科学与技术,2015,47(6):1-8.