本文已被:浏览 2893次 下载 33次
投稿时间:2013-01-06 修订日期:2013-03-13
投稿时间:2013-01-06 修订日期:2013-03-13
中文摘要: 采用慢应变速率拉伸实验研究了X100管线钢在 NS4 溶液中,在外加阴极电位下的应力腐蚀开裂行为。结果表明,与在自腐蚀电位下相比,-900 mV SCE外加阴极电位没有明显增强其近中性pH应力腐蚀开裂(NNpH-SCC)敏感性;但是,当外加阴极电位为 -1 500 mV SCE时,其 NNpH-SCC 敏感性显著增强。与 X80 管线钢在外加阴极电位下的NNpH-SCC敏感性相比较后表明,外加阴极电位对X80管线钢的NNpH-SCC敏感性影响更加强烈。
中文关键词: X100管线钢 外加阴极电位 NNpH-SCC 敏感性 慢拉伸实验
Abstract:Slow strain rate tests were conducted in deaerated NS4 solution to research the behavior of stress corrosion cracking of X100 pipeline steels at different applied cathode potential. The results showed that the susceptibility of near-neutral pH stress corrosion cracking(NNpH-SCC) does not increase obviously at -900 mV SCE than that at open circuit potential. However, the NNpH-SCC susceptibility increases distinctly at -1 500 mV SCE than that at open circuit potential. The NNpH-SCC susceptibility at applied cathode potential were contrasted between X100 and X80 pipeline steel, which revealed that the NNpH-SCC susceptibility influenced by applied cathode potential of X80 pipeline steel is stronger than that of X100 pipeline steel.
keywords: X100 pipeline steel applied cathode potential NNpH-SCC susceptibility slow strain rate tests
文章编号:201300011 中图分类号: 文献标志码:
基金项目:国家自然科学基金资助项目(11172188)
作者 | 单位 |
郏义征 | 四川建筑职业技术学院 博士后创新实践基地;四川大学 建筑与环境学院 |
李辉 | 四川建筑职业技术学院 博士后创新实践基地 |
胡楠楠 | 四川建筑职业技术学院 材料工程系 |
王清远 | 四川大学 建筑与环境学院 |
作者简介:
引用文本:
郏义征,李辉,胡楠楠,王清远.外加阴极电位对X100管线钢近中性pH值应力腐蚀开裂行为的影响[J].工程科学与技术,2013,45(4):186-191.
Jia Yizheng,Li Hui,Hu Nannan,Wang Qingyuan.Effects of Applied Cathode Potential on the Behavior of Near-neutral pH SCC of X100 Pipeline Steel[J].Advanced Engineering Sciences,2013,45(4):186-191.
引用文本:
郏义征,李辉,胡楠楠,王清远.外加阴极电位对X100管线钢近中性pH值应力腐蚀开裂行为的影响[J].工程科学与技术,2013,45(4):186-191.
Jia Yizheng,Li Hui,Hu Nannan,Wang Qingyuan.Effects of Applied Cathode Potential on the Behavior of Near-neutral pH SCC of X100 Pipeline Steel[J].Advanced Engineering Sciences,2013,45(4):186-191.