Abstract:For an aerator with sudden lateral enlargement and vertical drop in free flow chute
the cavity length is governed by a number of independent parameters
including the Froude number
the ramp height of vertical drop
the ramp angle of vertical drop
and the lateral enlargement width of sidewalls
etc.Based on model experiments
the effects of above-mentioned parameters were observed on the bottom cavity length and the lateral cavity length.The results showed that the bottom cavity length is closely related to the ramp height
the ramp angle
the lateral enlargement width and the Froude number
and with higher ramp height
bigger ramp angle
wider lateral enlargement width
and higher Froude number
the bottom cavity length is longer.Yet the lateral cavity length is mainly connected with the lateral enlargement width and the Froude number
which has little relation to the ramp height and the ramp angle.For the lateral cavity length
it increases with the lateral enlargement width.At the condition of larger size of lateral enlargement
the lateral cavity length increases linearly with the Froude number
while a little decreases when the size of lateral enlargement is smaller.