Abstract:Using the large size improved Hopkinson pressure bar with variable cross sections
a shock compression test with three kinds strain rates was carried out for the 100 mm diameter plain concrete and polypropylene fiber reinforced concrete specimens. The dynamic compression strengths and the overall process curves for stress strain of specimens under different strain rates were obtained. The experimental results indicated that under the shock compression with high strain rateloading condition
in the initial impact process
the tenacity of polypropylene fiber of reinforced concrete is roughly same with plain concrete
but with the impact proceeing some time
the tenacity of polypropylene fiber reinforced concrete is obviously better than plain concrete. The experiment provided the reference for the polypropylene textile fiber concretes in the protection project domain and military field's application.
关键词
分离式Hopkinson压杆聚丙烯纤维增强混凝土动态本构关系韧性冲击
Keywords
Split Hopkinson Pressure Bar (SHPB)poypropylene fiber reinforced concretedynamic constive relationtenacityimpact
references
Zhao H. ;Gary G.,ON THE USE OF SHPB TECHNIQUES TO DETERMINE THE DYNAMIC BEHAVIOR OF MATERIALS IN THE RANGE OF SMALL STRAINS,International Journal of Solids and Structures ,1996, 33(23).