Abstract:In order to fulfil the contour extraction of left atrial appendage (LAA) from the low resolution
low contrast and noisy transesophageal ultrasound images automatically
a new method was proposed
which combines the anatomical knowledge of LAA and the information of intensity and phase in ultrasound images. Firstly
to locate the effective initial contour with the characteristic of intensity and geometry from LAA ultrasound images
the anatomy location of LAA in the standard section is taken as the priori-knowledge based on the physicians’ collecting habit. Then
to improve the convergence performance of classical Vector Filed Convolution (VFC) model
a new external force term was proposed by combing phase and gradient information in the linear weighting method. According to the test results conducted from 300 frames
it shows that
this method can reach the accuracy of 0.8969 0.0494
sensitivity of 0.9058 0.0762 and specificity of 0.9645 0.1687 by regarding the contours outlined by physicians as “golden standard”. Comparing with traditional VFC model
this method owns better segmentation performance by determining a more suitable initial contour and is more robust to weak edge.